Four-Faith Modem(Dtu) UDP Data Format Document


Four-Faith Modem(Dtu) UDP Data Format Document

DTU UDP mode’s work process
After DTU repowered, it will dail up automaticafter sucessfulit will send register packet to server. When register is successful, the data can be transmitted between the DTU and server.

Data format (DTU send to DSC):

1.  Register packet
   
Start flag
Packet style
Packet length
DTU ID
DTU IP address
DTU port
Finish flag
1 byte
1 byte
2 bytes
11 bytes
4 bytes
2 bytes
1 byte
0x7b
0x01
0x16



0x7b

Note
        DTU ID  DTU RUIM card’s phone numbersuch as13312345678
        DTU IP address     IP Address which was assigned when DTU    PPP dail-up sucessful
        DTU port    DTU local port

2Data packet
      
Start flag
Packet style
Packet length
DTU ID
Finish flag
data
1 byte
1 byte
2 bytes
11 bytes
1 byte
Less 1024 bytes
0x7b
0x09
0x10

0x7b



The packet DSC send DTU

1.  The response packet to DTU:

Start flag
Packet style
Packet length
DTU  ID
Finish flag
1 byte
1 byte
2 bytes
11 bytes
1 byte
0x7b
0x81
0x10

0x7b

2The data packet  which DSC send to DTU
  
Start flag
Packet style
Packet length
DTU ID
Finish flag
Data packet
1 byte
1 byte
2 bytes
11 bytes
1 byte
Less 1024 bytes
0x7b
0x89
0x10

0x7b


2.  Logout packet which DSC send to DTU:


  
Start flag
Packet style
Packet length
DTU ID
Finish flag
1 byte
1 byte
2 bytes
11 bytes
1 byte
0x7b
0x82
0x10

0x7b